Technical specifications |
|
|
|
|
|
|
|
• |
Scale range ambiemt dose rate equivalent |
|
µSv/h |
0,05 ... 9,99 |
• |
Scale range exposition dose rate |
|
µRem/h |
5 ... 999 |
• |
Range energy scales - radiations |
|
MeV |
0,1 ... 1,25 |
• |
Reproducibility of indications (at confidential probability 0.95), where Ð is a dose rate in µSv/h |
|
% |
15+6/Ð |
• |
Levels of sound-alarm threshold |
|
µSv/h |
0.30, 0.60, 1.20 |
µRem/h |
30, 60, 120 |
• |
Time of calculation |
|
sec |
40±0.5* |
• |
Time of indication |
|
- |
continuously |
• |
Batteries of "AAA" type |
|
- |
one or two |
• |
Time of continuous work of a device, not less |
|
hour |
550 ** |
• |
Overall dimensions |
|
mm |
105x60x26 |
• |
Weight (without batteries) |
|
kg |
0,09 |
• |
The increase in cycles of calculation conducts to increase of reliability of indications. |
• |
Two batteries with a capacity 1350ÌAh, at a level of a natural background no more than 0,3 µSv/h and with factory settings. |